> For the complete documentation index, see [llms.txt](https://docs.weka.io/llms.txt). Markdown versions of documentation pages are available by appending `.md` to page URLs; this page is available as [Markdown](https://docs.weka.io/5.1/best-practice-guides/weka-and-kvm-integration/troubleshoot-kvm-integration-issues.md).

# Troubleshoot KVM integration issues

Review the following known issues and their resolutions when integrating WEKA with KVM.

<details>

<summary>VM has no SSH key or hostname after first boot</summary>

`cloud-init` caches per-instance state keyed on `instance-id`. If you reuse the same ID after recycling a disk, `cloud-init` skips all modules on first boot and the SSH key and hostname are not applied. Increment the `instance-id` in the `meta-data` block for each VM deployment, for example `iid-local01` → `iid-local02`.

</details>

<details>

<summary>Cloned VMs have conflicting identities</summary>

When cloning KVM VMs, every VM must have a unique and persistent `libvirt` domain UUID. Using `virt-clone` regenerates the UUID and MAC address automatically. A manual copy of the XML or disk does not regenerate these values and will cause conflicts.

</details>

<details>

<summary>WEKA DPDK crashes on guest VM startup</summary>

This occurs when Secure Boot is enabled in the VM. Use `OVMF_CODE_4M.fd` as the UEFI firmware, not `OVMF_CODE_4M.ms.fd`. The `.ms.fd` variant enables Secure Boot, which triggers kernel lockdown and blocks the `mpin_user` module required by WEKA DPDK.

</details>

<details>

<summary>Filesystem mount fails with "Missing ibverbs device"</summary>

The `mlx5_ib` kernel module is missing. Minimal cloud images do not include it. Fix:

```bash
apt-get install -y linux-modules-extra-$(uname -r)
modprobe mlx5_ib
```

</details>

<details>

<summary>Hugepages configuration is lost after reboot</summary>

The `grub.d` configuration was overridden by `cloud-init`. Use `/etc/default/grub.d/hugepages.cfg` to configure hugepages, not `GRUB_CMDLINE_LINUX` directly. Follow the hugepage configuration step in [/pages/99f26f0837b10f300cb971296f5ed65321599667#id-2.-configure-the-kvm-server](https://docs.weka.io/5.1/best-practice-guides/weka-and-kvm-integration/pages/99f26f0837b10f300cb971296f5ed65321599667#id-2.-configure-the-kvm-server "mention") procedure in Deploy the WEKA client on KVM virtual machines.

</details>

<details>

<summary>`RTNETLINK: Operation not supported` warning</summary>

This is a known `mlx5` switchdev limitation that appears when attempting switchdev configuration. It can be safely disregarded and does not affect functionality.

</details>

<details>

<summary>VF not binding correctly to vfio-pci</summary>

Use `driver_override` with `drivers_probe`, not `new_id`. The `new_id` method globally adds the device ID to vfio-pci probing. `driver_override` is per-device and is the correct method for mlx5 VFs. Follow the [/pages/99f26f0837b10f300cb971296f5ed65321599667#id-3.-set-up-vf-lag](https://docs.weka.io/5.1/best-practice-guides/weka-and-kvm-integration/pages/99f26f0837b10f300cb971296f5ed65321599667#id-3.-set-up-vf-lag "mention") procedure in Deploy the WEKA client on KVM virtual machines.

</details>

<details>

<summary>VF MAC frames not reaching the correct VF</summary>

Ensure you used `devlink port function set hw_addr` in switchdev mode. Generate and assign a unique MAC address for every VF. Follow the **Set VF MAC addresses** step in the [/pages/99f26f0837b10f300cb971296f5ed65321599667#id-3.-set-up-vf-lag](https://docs.weka.io/5.1/best-practice-guides/weka-and-kvm-integration/pages/99f26f0837b10f300cb971296f5ed65321599667#id-3.-set-up-vf-lag "mention") procedure in Deploy the WEKA client on KVM virtual machines.

</details>

<details>

<summary>100% ICMP loss after adding a dataplane IP to a bonded NIC</summary>

Never add the dataplane IP to a NIC that is part of a bonded LAG. If this was done, remove the address:

```bash
ip addr del <IP> dev $PF0_DEV
```

Adding an IP to a Physical Function during takedown causes ARP to resolve but packets to exit on the wrong interface.

</details>

<details>

<summary>`SoC on vfio-pci` message appears</summary>

This is a cosmetic message and can be disregarded. It does not affect the VF data path.

</details>

<details>

<summary>LACP bond members remain in monitoring state (ping works but no load balancing)</summary>

Switch-side LAG is not configured. Configure the LAG or port-channel with LACP on the upstream switch before creating the bond. Follow the LACP bond procedure in [Deploy the WEKA client on KVM virtual machines](/5.1/best-practice-guides/weka-and-kvm-integration/deploy-the-weka-client-on-kvm-virtual-machines.md). Without switch-side LACP, the bond operates as active-backup only.

</details>

<details>

<summary>MultiPorteSwitch (MPeSW) does not engage after a warm reboot</summary>

Perform a full power cycle using iDRAC/iLO chassis power off. A warm reboot is insufficient to reinitialize MPeSW.

</details>

<details>

<summary>`dmesg: VF BAR 0: can't assign; no space` error at VM boot</summary>

The PCIe MMIO window is too small. Lower `NUM_OF_VFS` in `mlxconfig`. As a secondary mitigation, add `pci=realloc=on` to the kernel command line.

</details>


---

# Agent Instructions
This documentation is published with GitBook. GitBook is the documentation platform designed so that both humans and AI agents can read, navigate, and reason over technical content effectively. Learn more at gitbook.com.

## Querying This Documentation
If you need additional information that is not directly available in this page, you can query the documentation by asking a question.

Perform an HTTP GET request on the following URL with the `ask` and `goal` query parameters:

```
GET https://docs.weka.io/5.1/best-practice-guides/weka-and-kvm-integration/troubleshoot-kvm-integration-issues.md?ask=<question>&goal=<user_goal>
```

`ask` is the immediate question: it should be specific, self-contained, and written in natural language.
`goal` is what the user is ultimately trying to achieve, the reason they need the answer. Sharing it helps GitBook give you a better, more relevant answer. A goal is most helpful when it describes the outcome the user wants rather than restating the question. For example, with `ask=how do I create an API token`, a goal like `automate deployments from our CI pipeline` lets GitBook tailor the answer to that use case.

The response will contain a direct answer to the question and relevant excerpts and sources from the documentation.

Use this mechanism when the answer is not explicitly present in the current page, you need clarification or additional context, or you want to retrieve related documentation sections.