For the complete documentation index, see llms.txt. This page is also available as Markdown.

Troubleshoot KVM integration issues

Review the following known issues and their resolutions when integrating WEKA with KVM.

VM has no SSH key or hostname after first boot

cloud-init caches per-instance state keyed on instance-id. If you reuse the same ID after recycling a disk, cloud-init skips all modules on first boot and the SSH key and hostname are not applied. Increment the instance-id in the meta-data block for each VM deployment, for example iid-local01 → iid-local02.

Cloned VMs have conflicting identities

When cloning KVM VMs, every VM must have a unique and persistent libvirt domain UUID. Using virt-clone regenerates the UUID and MAC address automatically. A manual copy of the XML or disk does not regenerate these values and will cause conflicts.

WEKA DPDK crashes on guest VM startup

This occurs when Secure Boot is enabled in the VM. Use OVMF_CODE_4M.fd as the UEFI firmware, not OVMF_CODE_4M.ms.fd. The .ms.fd variant enables Secure Boot, which triggers kernel lockdown and blocks the mpin_user module required by WEKA DPDK.

Filesystem mount fails with "Missing ibverbs device"

The mlx5_ib kernel module is missing. Minimal cloud images do not include it. Fix:

apt-get install -y linux-modules-extra-$(uname -r)
modprobe mlx5_ib
Hugepages configuration is lost after reboot

The grub.d configuration was overridden by cloud-init. Use /etc/default/grub.d/hugepages.cfg to configure hugepages, not GRUB_CMDLINE_LINUX directly. Follow the hugepage configuration step in 2. Configure the KVM server procedure in Deploy the WEKA client on KVM virtual machines.

VF not binding correctly to vfio-pci

Use driver_override with drivers_probe, not new_id. The new_id method globally adds the device ID to vfio-pci probing. driver_override is per-device and is the correct method for mlx5 VFs. Follow the 3. Set up VF-LAG procedure in Deploy the WEKA client on KVM virtual machines.

VF MAC frames not reaching the correct VF

Ensure you used devlink port function set hw_addr in switchdev mode. Generate and assign a unique MAC address for every VF. Follow the Set VF MAC addresses step in the 3. Set up VF-LAG procedure in Deploy the WEKA client on KVM virtual machines.

100% ICMP loss after adding a dataplane IP to a bonded NIC

Never add the dataplane IP to a NIC that is part of a bonded LAG. If this was done, remove the address:

Adding an IP to a Physical Function during takedown causes ARP to resolve but packets to exit on the wrong interface.

`SoC on vfio-pci` message appears

This is a cosmetic message and can be disregarded. It does not affect the VF data path.

LACP bond members remain in monitoring state (ping works but no load balancing)

Switch-side LAG is not configured. Configure the LAG or port-channel with LACP on the upstream switch before creating the bond. Follow the LACP bond procedure in Deploy the WEKA client on KVM virtual machines. Without switch-side LACP, the bond operates as active-backup only.

MultiPorteSwitch (MPeSW) does not engage after a warm reboot

Perform a full power cycle using iDRAC/iLO chassis power off. A warm reboot is insufficient to reinitialize MPeSW.

`dmesg: VF BAR 0: can't assign; no space` error at VM boot

The PCIe MMIO window is too small. Lower NUM_OF_VFS in mlxconfig. As a secondary mitigation, add pci=realloc=on to the kernel command line.