Manage traces using the CLI
Manage trace settings using the CLI commands:
Initiate trace collection
Stop trace collection
View traces configuration status
Modify traces retention settings
Adjust traces verbosity level to high or low
Manage the traces freeze period
Initiate trace collection
Command: weka debug traces start
Stop trace collection
Command: weka debug traces stop
View traces configuration status
Command: weka debug traces status
Modify traces retention settings
Command: weka debug traces retention set [--server-max server-max] [--client-max client-max] [--server-ensure-free server-ensure-free] [--client-ensure-free client-ensure-free]
Parameters
server-max
Maximum capacity to retain per server.
50GB per IO-node with a minimum of 100GB
client-max
Maximum capacity to retain per client.
50GB per IO-node with a minimum of 100GB
server-ensure-free
Always maintain at least this much capacity to remain free on servers.
50GB per IO-node with a minimum of 100GB
client-ensure-free
Always maintain at least this much capacity to remain free on clients.
50GB per IO-node with a minimum of 100GB
Restore default traces retention values
Command: weka debug traces retention restore-default
Adjust traces verbosity level
Command: weka debug traces level set <level>
Parameters
level
*
Verbosity level.
Format: low
or high
Manage the traces freeze period
View the frozen trace period
Command: weka debug traces freeze show
Set the freeze period
Command: weka debug traces freeze set <comment> [--start-time start-time] [--end-time end-time] [--retention retention]
Parameters
comment
*
A descriptive note providing context for easier tracking and review of debug traces.
start-time
The start time of the frozen period.
Format: 5m, -5m, -1d, -1w, 1:00, 01:00, 18:30, 18:30:07, 2018-12-31 10:00, 2018/12/31 10:00, 2018-12-31T10:00, 2019-Nov-17 11:11:00.309, 9:15Z, 10:00+2:00
end-time
The end time of the frozen period.
Format: 5m, -5m, -1d, -1w, 1:00, 01:00, 18:30, 18:30:07, 2018-12-31 10:00, 2018/12/31 10:00, 2018-12-31T10:00, 2019-Nov-17 11:11:00.309, 9:15Z, 10:00+2:00
retention
The time to retain the traces.
Format: 3s, 2h, 4m, 1d, 1d5h, 1w, infinite/unlimited
Reset the traces freeze period and delete the existing frozen traces
Command: weka debug traces freeze reset
Last updated